Turbine Flow Meter for Fuel, Oil, Air and Water

    Model NO.: LWGY
    Measuring Media: Liquid or Gas
    Measuring Principle: Atomic Physics
    Measurement Object: Closed Pipeline
    Certification: JIS, DIN, ANS, GB, CE, UL, RoHS, ISO
    Medium: Low Viscosity Clean Liquid, Air, Gas
    Pressure: Suitable for Very High Pressure
    Signal: Pulse, 4~20mA, Hart, RS485
    LCD: Yes/No
    Ex-Proof: Intrinsic Safety/ Explosion-Proof
    Trademark: U-ideal
    Transport Package: Wooden Case or Carton
    Specification: ISO
    Origin: Tianjin, China
    HS Code: 90261000
    Advantage: 
    1. Low weight, small volumn
    2. low cost, low price
    3. Good accuracy: 0.5%
    4. Is a type of digit flowmeter, also called electronic water flowmeter
    5. can be installed vertically or horizontally
    6. can be work at high pressure 10MPa
    7. connection method: ferrule (snap-on), flange, threaded

    1. Operating Principle:
     
    Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil. This signal is converted into engineering units (liters, cubic meters, gallons etc.) on the local display where is applicable. Optional accessory modules can be used to export the signal to other equipment.
     
    Upon receipt, examine your meter for visible damage. The turbine is a precision measuring instrument and should be handled carefully. Remove the protective plugs and caps for a thorough inspection. If any items are damaged or missing, contact U-IDEAL.
     
    Make sure the turbine flow model meets your specific needs. For your future reference, it might be useful to record this information on nameplate in the manual in case it becomes unreadable on the turbine. Refer to the nameplate for your customized product's specification.

    2. Technical Data 

     
    Measuring system  
    Application range   Liquid: water; diesel; gasoline
    1. Without Impurity
    2. Low viscosity
    Measured Value  
    Primary measured value   Flow Rate
    Secondary measured value   Volume flow  
     
    Design  
    Features    
    Modular construction   The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version.  
    Compact version converter  
     
     
    N Type: Pulse output without local display
    A Type: 4-20mA Output without local display
    B Type: Local Display; Lithium Battery Power;  
                  No Output
    C Type: Local Display; 24V DC Power; 4-20mA
    Output;  
    Optional Function:  
    1. Backup Power Supply: Lithium Battery
    2. Modbus RS485
    3. Pulse Output
    Connection
     
     
    Thread: DN4-DN50
    Flange: DN15-DN200 (DIN, ANSI, JIS)
    Wafer: DN15-DN100
    Measurement Ratio Standard - 10:1; Optional: 20:1
     


     
    Measuring accuracy  
    Reference conditions   Flow conditions similar to EN 29104  
    Medium: Water  
    Electrical conductivity: ≥ 300 μS/cm  
    Temperature: +10...+30°C / +50...+86°F  
    Inlet section: ≥ 10 DN  
    Operating pressure: 1 bar / 14.5 psig  
    Flow Meter Accuracy
     
    Standard: 1.0% of rate
    Optional: 0.5% of rate
     
    Operating conditions  
    Temperature  
    Process temperature   T1 Level: -20...+80°C  
    T2 Level: -20...+120°C  
    T3 Level: -20...+150°C  
    Ambient temperature
     (all versions)  
    Standard (with aluminum converter housing):  
    -10…+55°C  
    Storage temperature   -20...+70°
    Pressure  
     EN 1092-1   DN100…DN200: PN 16  
    DN15…DN80: PN 25
    Other pressures on request  
    ASME B16.5   1/2"...8": 150 lb RF  
    Other pressures on request  
    JIS   1/2"...8": 10 K  
    Other pressures on request  
     
    Installation conditions  
    Installation  
     
    Take care that flow sensor is always fully filled  
    For detailed information see chapter "Cautions for Installation"  
    Flow direction  
     
    Forward
    Arrow on flow sensor indicates flow direction.  
    Inlet run   ≥ 10 DN  
    Outlet run   ≥ 5 DN  
     
    Materials  
    Sensor housing   SS304  
    Other materials on request    
    Flanges  
     
    SS304  
    Other materials on request    
    Rotor     
    Standard: 2Cr13 EN10088-3       1.4021 X20Cr13
    AISI 420  
    BS 420S37  
    JIS SUS410J1  
    Optional: CD4MCu DN15…DN80  
    Bearings and Shaft Tungsten Carbide  
    Converter Housing Standard: polyurethane coated die-cast aluminum  
     
    Process connections
    Flange  
    EN 1092-1   DN15...200 in PN 6...40  
    ASME   1/2"…8" in 150 lb RF  
    JIS   1/2"…8" in 10...20K  
    Design of gasket surface   RF  
      Other sizes or pressure ratings on request  
    Thread DN4…DN50 in PN63
     
    Measurable Flow Rate Range:  
    Note: The flow range as blow is for reference only. Consult the factory if you have special requirement. Refer to the nameplate or certificate for actual flow range.
     
    Nominal Diameter Standard Flow Range   Extended Flow Range  
    (mm) (in.) (m3/h) (m3/h)  
    4 0.15 0.04 to 0.25 0.04 to 0.4
    6 0.25 0.1 to 0.6 0.06 to 0.6
    10 0.4 0.2 to 1.2 0.15 to 1.5
    15 0.5 0.6 to 6 0.4 to 8
    20 0.75 0.8 to 8 0.45 to 9
    25 1 1 to 10 0.5 to 10
    32 1.25 1.5 to 15 0.8 to 15
    40 1.5 2 to 20 1 to 20
    50 2 4 to 40 2 to 40
    65 2.5 7 to 70 4 to 70
    80 3 10 to 100 5 to 100
    100 4 20 to 200 10 to 200
    125 5 25 to 250 13 to 250
    150 6 30 to 300 15 to 300
    200 8 80 to 800 40 to 800
     

    3. Model and Selection 

    Model Selection (See Table 1)
     
    Table 1: Model Selection Guidance for Liquid Turbine Flowmeter
    Model Suffix Code        Description 
    LWGY-                  
    Diameter                  Three Digitals; for example:
    010: 10 mm;              015: 15 mm;
    080: 80 mm;              100: 100 mm                
    Converter  N No display; 24V DC; Pulse Output
    A No display; 24V DC; 4-20mA Output
    B Local display; Lithium Battery Power; No output
    C Local display; 24V DC Power; 4-20mA
    Output;  
    Optional backup power: Lithium Battery
    C1 Local display; 24V DC Power; 4-20mA
    Output; Modbus RS485 Communication
    Optional backup power: Lithium Battery
    H Local display; 24V DC Power;  
    4-wire 4-20mA Output & HART
    Communication
    Accuracy
    05 0.5% of Rate
    Flow Range  S Standard Range: refer to flow range table
    W Wide Range: refer to flow range table
    Body Material S SS304
    L SS316
    Explosion Rating N Safety Field without Explosion
    E ExdIIBT6
    Pressuring Rating   N Standard
    H(x) Customized Pressure Rating
    Connection     -DXX DXX: D06, D10, D16, D25, D40
    D06: DIN PN6; D10: DIN PN10
    D16: DIN PN16; D25: DIN PN25
    D40: DIN PN40
    -AX AX: A1, A3, A6
    A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
    -JX JX: J1, J2, J4
    J1: JIS 10K; J2: JIS 20K; J4: JIS 40K
    -TH Thread; DN4…DN50
    Fluid Temperature       -T1 -20...+80°C 
    -T2 -20...+120°C 
    -T3 -20...+150°C 
    Model Code: LWGY-050C10SSNN-A1-T1
    Explanation - Diameter: 50mm; Converter: 24V DC Power Supply, 4-20mA Output, Local Display
    Accuracy: 1.0%; Flow range: 4-40 m3/h; Body Material: SS304; No Explosion; Connection: ANSI 150# Flange; Fluid Temperature: -20…+80°C
    Turbine Flow Meter for Fuel, Oil, Air and WaterTurbine Flow Meter for Fuel, Oil, Air and Water

    Turbine Flow Meter for Fuel, Oil, Air and Water

    Nickel Based Alloy Powder

    Inconel Powder,Nickel Powder,Pta Welding Ni Alloy Powder,Laser Cladding Ni Base Powder

    Luoyang Golden Egret Geotools Co., Ltd , https://www.hvofpowders.com

    Previous Post: China Manufacturer Product Full-Automation Ceiling T Grid Roll Forming Machine
    Next Post: What are the factory direct aerial vehicles?
    Home
    Recent Posts
    • Shaft bottom yard form
    • Comprehensive comparison of leaf area determinat…
    • LED lighting demand is expected to usher in the …
    • CB115 Series Aluminium Module of Gravity Roller …
    • Talking about the Technical Essentials and Opera…
    • New application of titanium
    • Precision Aluminium Die Casting with Different F…
    • Garment /Textile/ Rubber/Plastic/Platform Needle…
    • Chemicals and Chemicals Manufacturing Industry V…
    • New Design Brake Shoes for Truck & Bus for Merce…
    • Ew020607 Swirl Ring (Ht2000, Max200 Plasma Cutti…
    • Corning 7980 Cylindrical Rod Lens Large Cylinder
    • Hubei Three Rings Transformation Upgrade Upgrade
    • Hydraulic Oil Filter (84202794) (P569206) (84278…
    • Dfq-400 DTH Hammer Drilling Machine
    • Cold Room Compressor Condensing Unit/Condenser U…
    • Bosch Group's 2015 sales exceeds 70 billion …
    • SANYU  Inverter pulse AC/DC welding machine (TI…
    • Turbo Compressor Trait Testing Equipment
    • Sandwich Wall panel Machine