3 Part Differential 22 Parameters Auto Hematology Analyzer

    Model NO.: HP-HEMA6000
    Parameter: 22
    Model No: HP-Hema6000
    Voltage: 98V-264V
    Operating Temperature: 10 Oc -35oc
    Trademark: hepomed
    Transport Package: Neutral Exporting Package
    Specification: ce iso sgs
    Origin: Zhengzhou of Henan

    HP-HEMA6000 Automatic Hematology Analyzer is mainly designed to detect the parameters of the series of red blood cells and hemoglobin,platelet and leukocyte in the blood.It is a requisite vitro diagnostic equipment which is applied to quantitative analysis of blood cells in clinical and laboratory.
    Model HP-HEMA6000
    Voltage 98V-264V 

    Advantages:
    1,Fully automated to increase productivity
    2,3-part differential cell counter with 22 parameter and laser light source
    3,Direct tube sampling from original collection vials for operator safety
    4,Bar code capability to reduce manual input
    5,Proven technology to provide accurate results
    6,More than 60 samples per hour
    7,Minimum maintenance required

    The machine is mainly used for the quantitative measurement of the blood in the 19 parameters and 3 histograms:
    1   The total amount of WBC                                                                                  WBC
    2   The amount of Lymphocyte                                                                               Ly#
    3   The amount of Monocyte                                                                                   MO#
    4   The amount of Granulocyte                                                                               GR#
    5   Lymphocyte percentage                                                                                    Ly%
    6   The percentage of mononuclear cells                                                              MO%
    7   Granulocyte percentage                                                                                    GR%
    8   The total amount of red blood cells                                                                  RBC
    9   Hemoglobin                                                                                                        HGB
    10   Hematocrit                                                                                                        HCT
    11   Mean volume of red blood cells                                                                     MCV
    12   Mean corpuscular hemoglobin                                                                      MCH
    13   Mean corpuscular hemoglobin concentration                                              MCHC
    14   Red blood cell volume distribution width Coefficient of variation              RDW-cv
    15   The standard deviation of red blood cell volume distribution width           RDW-sd
    16   The total amount of platelet                                                                            PLT
    17   Mean platelet volume                                                                                      MPV 
    18   Plateletcrit                                                                                                        PCT
    19   Platelet distribution width                                                                               PDW
    20   White blood cell distribution histogram                                                        WBC Histogram
    21   Red blood cell distribution histogram                                                           RBC Histogram
    22   Platelet distribution histogram                                                                       PLT Histogram

    Main Parameters:
     - 1.Use impedance method for RBC and platelet count 
     - 2. Cyanide free for Haemoglobin test
     - 3. Flow cytometry +laser light scatter + chemical dye method for WBC differential analysis
     - 4.Fully automated with an autoloader and sampler
     - 5. Should use both closed tube sampling and open tube sampling
     - 6. 2 counting mode, whole blood and pre-diluted mode
     - 7. With histograms and scattergrams for differential results
     -8. Throughput of at least 60 samples per hour 
     -9. Automatic flagging system for abnormal results and automatic sample re-run 
     -10. Automatic validation of results on a dedicated PC with at least a 10.4" colour monitor
     - 11.Data storage capacity of at least 20,000 results
     - 12.Optional integrated slide maker and on-board cytology atlas
     - 13.Optional colour printer an on-board diagnostics
     - 14.Flexible communication/connection (USB)
     - 15.Operating temperature of 10 oc -35oc and humidity of up to 85%
     -16. Floppy disc drive and DVD writer 
     -17. Power 98V-264V 
     -18. The equipment should be accompanied with all manufacturers' recommended spare parts

    Supply one year quanlity guarrantee for main body and free training 2 persons for first time.Reagents can be supplied by original produced by ourselves.Various technical support and maintanance suggest by our professional application engineers and sales engineers.

    Refrigerant Cleaning Machine

    We have two items of R1234yf Machine . One machine is Refrigerant RRR Machine, the other one is Refrigerant Cleaning Machine.


    The function of Refrigerant RRR Machine:


    • Free separation and cleaning of air conditioning refrigeration system
    • Automatic and manual recovery and recharge of R1234yf refrigerant, evacuation, oil filling
    • Automatic discharge of Refrigerant Oil
    • Refrigerant purification and regeneration
    • Automatic discharge of non-condensing gas
    • System error prompt

    The R1234yf machine is one of the first machines for recovering, recycling, and recharging vehicle A/C systems with the new R1234yf Refrigerant. Services both standard and hybrid vehicle A/C systems. Features an integrated refrigerant identifier that samples the R1234yf Refrigerants in an A/C system before recovery. Fully automatic operation without contiinual monitoring.

    The premium refrigerant (RRR) machine automatically recovers, recycles, evacuates, leak tests, and recharges with 98.5% efficiency. Automatic features include leak testing, refrigerant refill, and oil drain/inject, putting A/C lubricant back into the system, plus air purge and refrigerant refill.


    The function of Refrigerant Automatic Cleaning Machine:

    • Diagnosis
    • Recovery
    • Recycling
    • Recharge

    Fully automatic design to help the mechanic facilitate air conditioning inspection and troubleshooting.

    Recovers 99% efficiency of air conditioning.

    Made in China, quality guaranteed.

    Work only in vehicles with R1234yf refrigerants.








    Refrigerant Cleaning Machine,Refrigerant Automatic Cleaning Machine,Pipe Refrigerant Cleaning Machine,Refrigerant Cleaning Equipment

    Shenyang Zhongda Huanxin Refrigeration Technology Co., Ltd. , https://www.zdhxrefrigerant.com

    Previous Post: 12.84ton Industrial Scroll Type Water Cooled Water Chiller
    Next Post: Air Cooled Water Chiller with Screw Compressor
    Home
    Recent Posts
    • Carbon Fiber Clock Backing Plate for Triumph/Spe…
    • Semi-Metal High Performence Brake Pads for Japan…
    • 1t Brima Manual Chain Block
    • 5.7 Meters Electric Shuttle Bus, Ce Approval
    • Van and Cargo Semi Trailer for Sale
    • Alcohol chopper banned contraband successfully p…
    • China's equipment manufacturing industry: a …
    • High Quality Three Wheels Drive Cargo Dumper, Mi…
    • High Quality Semi Metal Auto Brake Pad D0243-715…
    • 4X2 electric truck long distance driving range, …
    • Mini Truck Diesel for Sale
    • · Due to steering safety hazard Changan Mazda r…
    • Semi-Metal Friction Brake Pads 04465-Yzz51 for T…
    • D340 Brake Pad Backing Plate
    • Pulsar135 Motorcycle Part
    • China Mini Pickup Truck Light Cargo Truck for Sa…
    • Diesel Engine Portable / Mobile Screw Air Compre…
    • Narrowband Internet of Things NB-IoT Technology …
    • Application and development of domestic HTG cera…
    • New Chinese Reverse Trike