Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

    Model NO.: GC5891N
    Trademark: Haida
    Transport Package: Strong Wooden Case
    Origin: Guangdong, China
    Model NO.: GC5891N
    Trademark: Haida
    Transport Package: Strong Wooden Case
    Origin: Guangdong, China
    Laboratory Gas Chromatography Instrument For Dissolved Gas In Transformer Oil
     
    Description:
    The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.

    Application:
    Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.

    Parameter:
    (The table parameters for the company Standard Model parameters, we support customer customization parameters)
    Column temperature Box
    Furnace Size 28×30×18cm
    Temperature control Range higher than room temperature 5ºC~450ºC; Use liquid nitrogen cold well -80ºC~400ºC; use dry ice trap -55ºC~400ºC
    Temperature setting accuracy 0.1ºC
    Maximum program heating rate 120ºC/min
    Maximum once method run time 999.99min
    Maximum class of program heating 7 class
    Programmed Temperature Rate 0.1~120ºC/min (increment 0.1 ºC)
    Operation Column loss compensation (dual channel)
    Heating Zone
    Heating Zone
    Heating Zone
    6 Independent control heating zone (excluding furnace temperature control, two inlet, two detectors, two auxiliary heating areas)
    Maximum operating temperature in auxiliary heating zone 300ºC
    Detector
    Hydrogen Flame ionization detector FID
    Maximum operating temperature 450ºC
    Minimum check out limit ≤2.5pgC/s [n-C16]
    Dynamic linear Range ≥107(±10%)
    Data acquisition Frequency 100Hz (MAX)
    Thermal conductivity Pool Tester TCD
    Maximum operating temperature 400ºC
    Minimum check out limit <400pg C3H8/ml(He)
    Dynamic linear Range 105(±5%)
    Data acquisition Frequency 100Hz (MAX)
    Flame Photometric Detector FPD
    Maximum operating temperature 250ºC
    Minimum check out limit <4pgC/sec,<1pg P/sec
    Dynamic linear Range >103S,>104P
    Selective <4pgC/sec,<1pg P/sec
    Electronic Capture Detector ECD
    Maximum operating temperature 400ºC
    Detector compensation Gas Type 5% Methane/Argon or nitrogen
    Minimum check out limit <0.01Ppg/s lindane
    Dynamic linear Range >5×1055
    Data acquisition Frequency 100Hz (MAX)
    Radioactive sources <12mCi  63Ni
    Nitrogen and Phosphorus detector NPD
    Maximum operating temperature 450ºC
    Minimum check out limit <0.2 pg N/sec,<0.2 pg P/sec
    Dynamic linear Range 105N,105P
    Minimum check out limit <0.3pg C/Sec
    The above detectors are suitable for filling column and capillary column
    Anti-control software Optional configuration (Automatic injection B6891N)
    (The table parameters for the company Standard Model parameters, we support customer customization parameters)

    Performance:
    1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
    Micro-channel Air Circuit Integrated Board
    All-imported miniature proportional valves and flow/pressure sensors
    Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi

    2.Industry-Leading Detector design
    All detectors are high-precision electronic flow/pressure control
    Fit and fill column and capillary column
    Special ceramic treatment of the enlarged plate, in the humid season is always stable

    3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable

    4.Accurate furnace temperature tracking design

    5.Independent Heating small column box

    In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.

    6.Fully Imported Valve configuration system
    Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;

    7.Precise temperature control of the programmed furnace
    Furnace internal control accuracy less than 0.01°c
    The temperature difference between the internal points is not more than the °c
    Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
    Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)

    8.The convenient realization of gas cutting technology
    Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
    It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.

    9.Advanced Power Distribution Management shunt
    A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed

    10.Automatic injection
    8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)

    11.Automatic Online inspection function




    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

    The introduction of Haida
    Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.

    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

     
    Packaging & Shipping:
    Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

     
    After-service:

    If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.



     
    Laboratory Gas Chromatography Instrument For Dissolved Gas In Transformer Oil
     
    Description:
    The entire new generation of laboratory high-end automatic gas chromatograph gc6891n, the basic international most advanced technology platform and decades of international industry technology application experience, function, reliability and application flexibility, etc. in the industry leader.

    Application:
    Oil extraction and refining, petrochemical, fine chemicals, food safety, environmental protection, electronic high purity gas industry, research institutes, quality inspection, safety supervision, police forensic and national security and other fields of analysis and detection.

    Parameter:
    (The table parameters for the company Standard Model parameters, we support customer customization parameters)
    Column temperature Box
    Furnace Size 28×30×18cm
    Temperature control Range higher than room temperature 5ºC~450ºC; Use liquid nitrogen cold well -80ºC~400ºC; use dry ice trap -55ºC~400ºC
    Temperature setting accuracy 0.1ºC
    Maximum program heating rate 120ºC/min
    Maximum once method run time 999.99min
    Maximum class of program heating 7 class
    Programmed Temperature Rate 0.1~120ºC/min (increment 0.1 ºC)
    Operation Column loss compensation (dual channel)
    Heating Zone
    Heating Zone
    Heating Zone
    6 Independent control heating zone (excluding furnace temperature control, two inlet, two detectors, two auxiliary heating areas)
    Maximum operating temperature in auxiliary heating zone 300ºC
    Detector
    Hydrogen Flame ionization detector FID
    Maximum operating temperature 450ºC
    Minimum check out limit ≤2.5pgC/s [n-C16]
    Dynamic linear Range ≥107(±10%)
    Data acquisition Frequency 100Hz (MAX)
    Thermal conductivity Pool Tester TCD
    Maximum operating temperature 400ºC
    Minimum check out limit <400pg C3H8/ml(He)
    Dynamic linear Range 105(±5%)
    Data acquisition Frequency 100Hz (MAX)
    Flame Photometric Detector FPD
    Maximum operating temperature 250ºC
    Minimum check out limit <4pgC/sec,<1pg P/sec
    Dynamic linear Range >103S,>104P
    Selective <4pgC/sec,<1pg P/sec
    Electronic Capture Detector ECD
    Maximum operating temperature 400ºC
    Detector compensation Gas Type 5% Methane/Argon or nitrogen
    Minimum check out limit <0.01Ppg/s lindane
    Dynamic linear Range >5×1055
    Data acquisition Frequency 100Hz (MAX)
    Radioactive sources <12mCi  63Ni
    Nitrogen and Phosphorus detector NPD
    Maximum operating temperature 450ºC
    Minimum check out limit <0.2 pg N/sec,<0.2 pg P/sec
    Dynamic linear Range 105N,105P
    Minimum check out limit <0.3pg C/Sec
    The above detectors are suitable for filling column and capillary column
    Anti-control software Optional configuration (Automatic injection B6891N)
    (The table parameters for the company Standard Model parameters, we support customer customization parameters)

    Performance:
    1.Inlet flow rate, chromatographic column load flow, detector gas flow, complete EPC control
    Micro-channel Air Circuit Integrated Board
    All-imported miniature proportional valves and flow/pressure sensors
    Automatic temperature compensation ensures accurate flow and pressure control to 0.01Psi

    2.Industry-Leading Detector design
    All detectors are high-precision electronic flow/pressure control
    Fit and fill column and capillary column
    Special ceramic treatment of the enlarged plate, in the humid season is always stable

    3.Automatic ignition, hydrogen leak automatic protection function, safe and reliable

    4.Accurate furnace temperature tracking design

    5.Independent Heating small column box

    In the multi-column chromatographic system, the temperature of different columns can be set respectively, so as to achieve the best separation effect of each column.

    6.Fully Imported Valve configuration system
    Up to 8 valves (four-pass valve, six-pass valve, ten-pass valve and liquid injection valve optional); Automatic control, sequence operation;

    7.Precise temperature control of the programmed furnace
    Furnace internal control accuracy less than 0.01°c
    The temperature difference between the internal points is not more than the °c
    Rapid heating and cooling, the highest program heating speed: 120ºC/min, balance time 10 seconds, cooling time 300°c~50°c 6 minutes
    Absolute control of the temperature accuracy (with the actual temperature difference is less than 0.3C)

    8.The convenient realization of gas cutting technology
    Multi-dimensional chromatographic function to complete the separation and analysis of complex samples
    It can realize the inverse blowing function of chromatographic column to save the analysis time and cycle greatly.

    9.Advanced Power Distribution Management shunt
    A 3000 watt UPS can provide 10 units of normal power 2250 watts/set of GC stable working power supply automatic Feed

    10.Automatic injection
    8-bit automatic injection device (optional Agilent 7683/7693 liquid automatic injection)

    11.Automatic Online inspection function




    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

    The introduction of Haida
    Haida products are widely used in paper products, packaging, ink printing, adhesive tapes, bags, footwear, leather products, environment, toys, baby products, hardware, electronic products, plastic products, rubber products and other industries, and are applicable to all scientific research units, quality inspection institutions and academic fields. Our products meet UL, ASTM, JIS, GB,SO, TAPPI, EN, DIN, BS and other domestic and international standards.

    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

     
    Packaging & Shipping:
    Simulation Animatronic Customer Triceratops are covered with air bubble film before put them into the wooden case, which not only has good shock absorption, impact resistance, heat sealing and also has the advantages of nontoxic, odorless, moisture corrosion, good transparency etc.

    Laboratory Gas Chromatography Instrument for Dissolved Gas in Transformer Oil

     
    After-service:

    If you face any problems in future during testing process we promise we will give you a reply within 48 hours and solution provide within 3 working days. We can offer operation video and English operation muanual. We can provide video-con.



     

    Clamp-in Metal Tire Valve

    Clamp-In Metal Tire Valve,Metal Tire Valves,Tire Pressure Monitoring Valves,Tubeless Type-Truck Tire Valve

    Ningbo Kaisheng Auto Parts Co.,Ltd , https://www.valvestemfactory.com

    Previous Post: 5HP Low Temperature Industrial Water Chiller
    Next Post: Syria will require importers to print company names on the cargo label column
    Home
    Recent Posts
    • Hot Runner Pet Preform Injection Mould 32 Cavity
    • High Quality Flange Screw Flange Bolt Hex Bolt w…
    • Ce/ISO Approved Medical High Quality Baby Scale …
    • Rotating CIP Spray Ball Tri Clamp 304 Stainless …
    • Carbon Steel Zinc Plated Serrated Hex Flange Bol…
    • OEM/Custom Precision Metal/Iron/Steel Forge/Forg…
    • Two Roll Open Mill of Rubber Mixing Machine
    • ISO 9001 Factory Price Security Electric Plastic…
    • roof steel sheet PU Sandwich Panel Rolling Formi…
    • Stud / Studless Link Anchor Chain Ship Anchor Ch…
    • Renmin University of China makes cheap and scala…
    • Ys-Fb450 4.5m High Quality Food Truck Mobile Res…
    • Original Security High Sensitivity Walk Through …
    • Air Conditioning Water System Using Chemical Dos…
    • High Torque Co-Rotating Parellel Twin Screw Extr…
    • Hot Selling Hfj-C Type Long Hydraulic Floor Jack
    • Lab Twin Screw Extruder for Master Batch
    • Domestic robot market has great potential
    • Latest Ele6060 Small Table Top Milling Machine D…
    • High Sensivity Conveyor Belt Industrial Metal De…