Common troubleshooting of magnetic separator

    1. Pouring the mine end

    Reason 1: The amount of ore is too large and the ore is uneven. The reason for the large amount of ore is that the ore is too large for the grinding operation, the mill is rough, and the amount of ore is reduced.

    Reason 2: The slurry pump is not adjusted well, causing the pump to gasp, the flow rate is suddenly large and small, the slurry pump is adjusted, and the flow is stabilized;

    Reason 3: The bottom of the tank is clogged, causing the magnetic separator to reduce the throughput and flushing the tank with a water pipe;

    Reason 4: The unloading clearance is too small, and the maintenance personnel are notified to adjust;

    Cause 5: The working gap of the tank is too small, which affects the throughput of magnetic separation.

    2. The ore level is too small or the concentrate is discharged.

    Reason 1: Block the mine pipe or the mine gate, and clear the mine pipe and gate;

    Reason 2: Most of the bottom of the tank is clogged or full, mainly because the grinding is too thick, causing the flushing water pipe to rush and block;

    Reason 3: The tank or tailings pipe is worn out. Because the wear or the installation of the flushing water pipe is not correct, the bottom tank or the tailings pipe is leaked, so that the ore is directly leaked into the tailings;

    Reason 4: The magnetic declination is reversed or small, which will not only cause the ore to mine, but also affect the discharge of concentrate.

    3. The magnetic separator with load runs suddenly stops

    For whatever reason, the magnetic separator must stop pressing the stop button first, and stop the Valve to find the reason:

    Reason 1: The debris in the tank enters the cylinder, or the wear-resistant layer falls off and blocks the cylinder. The accident valve is opened to remove the debris, and the wear-resistant layer is cut off.

    Cause 2: The power supply system or the power distribution system is faulty. If it is an electrical fault, it must be handled by an electrician. Do not do it yourself;

    Reason 3: The transmission system of the transmission part is faulty or the slurry or magnetic block falls off in the cylinder body, and the maintenance personnel are inspected.

    4. There is sound in the cylinder, there is sound outside the cylinder

    Reason 1: Individual magnetic blocks in the magnetic system fall off

    Due to the long-term operation of the equipment, the individual magnetic blocks are not firmly bonded or the adhesive is aged, and the magnetic block fixing bolts loosen and fall off, which may cause the magnetic blocks to fall off. The wear of the magnetic separator is such that the gap between the magnetic system and the cylinder becomes smaller, so that the individual magnetic blocks first touch the cylinder and rub off, causing frictional friction, and in serious cases, the cylinder is worn out. In this case, the leader should report to the leader and arrange for maintenance personnel to overhaul:

    Reason 2: The gap between the magnetic system and the cylinder is too small or the cylinder is not round

    The gap between the magnetic system and the cylinder is generally required to be between 2-3 mm. If the gap between the magnetic system and the cylinder is too small, or the roundness of the cylinder is not enough, the magnetic system is at a higher point, and the magnetic system and the inside of the cylinder will be rubbed. I can't even move. Mainly in the assembled magnetic system, ash, sand, crushed scrap iron or magnet block sandwiched causing junction portion of the magnetic system, such as found in this case must be out of the magnetic system, reassemble the cylinder body.

    Compressor

    World-HVACR technologies - A WORLD OF COOLING AND HEATING COMPRESSORS. Redscrew is a technical private enterprise specialized in supplying different brands compressors for Commercial and Residential Air Conditioning, Refrigeration, Heat pump and other industrial applications.
    Since incorporated in 2006, our compressors have been used by facilities and plant maintenance personnel worldwide for the production of A/C and refrigerating equipment and maintenance of HVAC systems.

    Compressor,Portable Air Compressor,Small Air Compressor,Spring Compressor

    Hangzhou Refworld Mechanic&Electric Co.,Ltd , https://www.refworldrefrigeration.com

    Previous Post: DIN933 DIN931 Asme Brass Hex Cap Screw with ISO Certificate
    Next Post: Trunnion Mounted Gear Operated Ball Valve
    Home
    Recent Posts
    • High Quality 1/2′′inch Brass Valve Cartridge…
    • Water Meter Lockable Ball Valve
    • DIN 6914 Heavy Hex Structural Bolt with Nut and …
    • Galvanized Flange Bolt with Hex Head
    • in-Sail Steel Hex Self Tapping Screw (TAP010)
    • Auto Parts Cylinder Block for Cummins Isl Isle 6…
    • Corrosion protection grounding body anti-corrosi…
    • Pneumatic Rubber Fender Also Called Yokohama Fen…
    • Minerals & Metallurgy Casting Iron Die Cast Alum…
    • 1PC Stainless Steel High Quality Flanged Ball Va…
    • Lockable Wafer Ball Valve with ISO5211 Mouting P…
    • Excavator Spare Part 01011-62400 Hexagonal Bolt
    • Special Non-Standard Hexagonal Punching Screw Bo…
    • Double Flat Head Chipboard Screw
    • Painted Hex Washer Head Self Drilling Screw with…
    • Aluminum Final Saw with Chip Collector in Alumin…
    • "Small" has something to do: Case CX36…
    • One Year Quality Warranty Steel Hex Cap Nut
    • Tianlong Tanker
    • Poultry and livestock disease inspection vehicle…